Insulating A Flat Roof
83
Flat roofs have been a daunting task for contractors and homeowners alike since they were invented. They are hard to waterproof, hard to maintain, and hard to insulate. For today's purposes, we will stick with the insulation issue.
In order to properly insulate a flat roof area, you need to be very carefull on the material and the methods used. I will break these into sections for organizational purposes:
Insulation Between Ceiling Rafters
There are only 2 types of insulation that should be used for this method. Spray foam (either closed or open cell) insulation or dense pack cellulose insulation. The reason is because it is very difficult to properly ventilate a flat space because air does not generally move in a straight line. This invites moisture into an area that if trapped, can do a lot of damage and is hard to get rid of. It is much easier and more efficient to have a non-ventilated area and fill the entire cavity full with dense pack cellulose, or seal the area with 4 to 5 inches of spray foam.
One consideration is rafter hieght. If you only have 2x6 rafters existing, you will only be able to use closed cell spray foam insulation to insulate with because of the R-value restrictions (closed cell foam is R-6 per inch, open cell foam is R-3.5 per inch, and cellulose is R-3.8 per inch). If you have at least 2x8's for rafters, then you can use dense pack cellulose or open cell spray foam.
The closed cell spray foam option costs about $4/square foot. Open cell foam costs about $2.75/square foot. Cellulose insulation costs about $1/square foot. FIBERGLASS INSULATION SHOULD NEVER BE USED IN AN AREA LIKE THIS.
Insulating On The Exterior Roof Surface
This is probably the most popular method for commercial roofs, but can be utilized for residential flat roofs also. This is done by applying a strong adhesive to the foam board, laying it down on the roof surface, and securing with washer head nails. Then the rubber waterproof membrane is adhered to the surface of the foam board. Two or more layers of foam board are normally used in this application to achieve the needed R-value. Again, no ventilation needs to be present. In this application, the ceiling joist spaces may remain empty. Always remember that if this method it used, the rim joists still need to be insulated to keep the insulation continuous from roof to wall to avoid moisture and air infiltration issues.
Insulating The Ceiling
This method is not recommended because the ceiling height would have to drop at least 4 inches to meet code requirements. It also makes future addition of lighting or hardware very difficult.
As you can see, there are limited options available that are truly correct ways to insulate and air seal without having moisture or air infiltration issues. This is why flat ceilings are not a popular construction method for residential use. However, if the proper insulation methods and materials are used, you can have a wonderfully insulated roof.
If you are unsure of what energy improvements to make, it is always a good idea to hire an energy consultant. They will walk through your building with you and show you the areas that can benefit from energy efficiency improvements.
vote upvote downshareprintflag
- Useful (1)
- Funny
- Awesome (1)
- Beautiful
- Interesting (1)
CommentsLoading...
Really something to think about.Insulating the ceiling was never easy.
Article was very informative. Thanks
I have a situation similar to scenario 3. I live in DC in an old house built in the 1930's with limited to no insulation in the roof cavity. I also have existing Air Conditioning ductwork (added in after the house was built) up in the cavity since my AC unit is on the roof. I need a new roof and I am looking at getting a Coolstar white reflective membrane, but I am trying to figure out how to best insulate. I'm trying to figure out how thick and how much R value the rigid insulation should have if I put it on the top of the roof (scenario 3A). But I am also worried since I read that having the rigid insulation on the "cool side" of the roof in the winter could trap moisture in the cavity and lead to mold issues. It seems like the best thing to do would be to go with the reflective membrane, but do blow-in insulation above the drywall ceiling, but I am worried that system would be harder to install given all the ductwork up there and the fact that I have old plaster ceilings. It doesn't seem like any solution is a good one!!! Do you have any advice? Thanks so much!!!
Thanks for the input. I have pretty much decided to go with the rigid insulation on the roof rather than spray, and I will also make sure to insulate at the front and rear wall perimeter above the ceiling (it's a row house so the sides are bordered by other houses).
Where I am still a bit torn is on how much R value to make sure the rigid insulation has. Check out these two calculator sites I found.
http://www.builditsolar.com/References/Calculators
http://www.builditsolar.com/References/Calculators
They seem to indicate that in my situation (being in DC which isn't as cold as say upstate new york), anything more than a 15 R value on the roof (since its only 700 sf of area) will not be too cost effective and wont save that much additional fuel costs.
I know these calculators may not be very accurate (and their creator admits the error they may have), but they are the best I could find online for helping you get an idea of the bigger picture.
I'd be interested to hear your thoughts on these. Thanks again for all the help!!!
Another super cool site that gives you historical data on Heating Degree Days and Cooling Degree Days in different zip codes...
I have a flat roof in a very old building approx 10 feet high. I want/need the roof insulated b/c its freezing in the winter. I have reason to believe that if I pop out vent holes on both ends of the joist span and leave a 4 inch gap between the roof and insulation I can then have a great passage way for air flow and still have the roof insulated with Batt style just under the gap.
OR
I can cut out rectangular shapes to fit a register cover to allow air flow from the inside of the building to flow thru and still insulate with a batt style with a gap between the roof and the insulation and a vapor barrier underneath the insulation?
Please let m e know what you think...
Great information on this page. My situation is a little different. I live in Ontario, Canada and R-45 is the mimimum recommendation for attic insulation. I have a built up roof that has been covered by a conventional peaked roof. For the built up part from the warm side I have drywall, paper backed batt insulation (not sure of the r value but it is only about 3 inches thick and the paper is towards the drywall), then a 5" airgap (I don't see any venting to the outdoors ) then the built up portion. The peaked roof is traditional and has all kinds of venting, eaves, peak and through the sides.
Now for the question. How would I go about adding a vapor barrier to this system? Is the built up roof a vapor barrier in itself? The paper backed insulation is obviously not working. Could I remove the drywall and existing paper back insulation, replace and completely fill the cavity with new batt insulation then cover that with a poly vapor barrier and re drywall? If going the foam route could I leave the existing batt insulation in there and just fill the cavity through holes in the drywall with low expanding closed cell foam?
Thanks,
D.
I have a flat concrete roof about 6 inches thick. I'm considering spray roofing or laying foam sheathing with asphalt/tar to stick the sheathing on. I thought maybe a 3/4" sheathing with an r5 value might be good. What would be the best way to insulate this type of roof?
Thank you for this information was beautiful and successful work,
roofing membrane film that creates professional helpers do not prefer covers, eco-and nano-technology and specially developed for the exchange of breath, and healthy both seals is not flammable
The best roof green roof, eco roofs should become compulsory by law
Enclosing an attached porch with a flat roof that
vents part of the house attic across the 6 inch rafters to the vents in the eve. I want to insulate, mainly to keep the cold in and the heat out (house is in central florida). What would be the best method to use. Should I fill the six inches between the roof and the ceiling or should I leave an inch or two away from roof for ventilation to eve?
I have a flat roofed house built in the late 80's. The roof assembly consists of 2 x 10's with 2 x 4's running perpendicular across the top of them to create an air gap of 3 to 5" (varied to create drainage) below the sheathing and roof membrane. The 2 x 10's have pink fiberglass batts in between them measuring about 8 to 9" deep. i have much of the drywall down as part of a renovation and am now considering whether to invest in changing the insulation. If I go with spray foam, do I apply it to the underside of the sheathing and if so, will this cause any problems with respect to over heating the roof membrane?
In addition to my roofs, I have a number of decks over heated spaces that have a similar construction. They have just have new membranes installed as there were some leak issues. the insulation has been removed as part of the repair process. What insulation should I install and if I choose closed cell spray foam, what happens if i get another water leak? Will it mask the source leading to greater problems later?
Thanks in advance for your advice.
Thanks! I hadn't thought of batts and foam. Your comment reminded me of a recent Fine Homebuilding article suggesting that idea as a way to cut costs compared to using foam alone.
I will follow your advice. Thanks again.
This article and the dialogue in the comments is very helpful. I still am stumped about my situation, though.
I have a 7" tall cavity between 16" spaced 2x8's that both hold up a (very slightly sloped) flat roof on the top side and drywall for the ceiling on the bottom side. There is currently one layer of R13 fiberglass batt laid into each cavity, but the cavities themselves are very drafty. There must be vents at the ends of channels, but they are not visible/accessible. As a result, I basically live in a place with a continously refrigerated or heated ceiling, which makes it expensive to maintain comfortable conditions.
Because I cannot take down the ceiling, whatever insulation choice I make must involve injection through holes cut through the ceiling into each channel. That means that spray foam is out but injection foam might work. (I've already excluded blown in dense pack cellulose and fiberglass due to the risk of moisture damage to the roof deck.) I understand that closed cell foam could provide both an air and vapor barrier (true?) as well as additional thermal insulation if installed on top (or beneath?) of the existing fiberglass batt. I saw your recommendation of a combination of foam plus blown in fiberglass for another commenter, but I don't think it's possible through an injection application to do anything but the whole 7" with foam.
Although I am confused by the various closed-cell foam types on the market (and I haven't found a good website for comparison), my question is more general: Would you advise this kind of 'cathedral ceiling' type approach to retrofiting a (basically) flat roof with insulation?
I have a flat roof ranch house. I am currently remodeling. 2x10 roof joists 1x8 plank decking torch down modified roofing on top of that. Cavities are open to soffit around perimeter of house with soffit vents. There originally was r13 fiberglass with large air gap above, rock lathe and plaster ceiling with foil backing for moisture barrier. I finished a room already and filled the roof cavity with r30 bats, then someone told me that was wrong. Can't blow in because it would just shoot outside thru soffit vents. My idea was foam baffles on underside of decking then pack in r30, then I would filling the cavity but still leaving 2" air gap for ventilation. I don't want to get rid of the ventilation because of how hot the roof get in the summer. Any thoughts?
plz send me detail on my at rawat.sumit09@gmail.com
Hi, I am looking at buying a 1959 home with a flat roof. It has 3 foot overhangs and no gutters, just little u shape spouts at spots on edge. Inside I see laminated beams and tung and grove pine or cedar planking as roof surface. Outside on the roof I see white gravel and some black material. First would a home of this age have an insulation layer under the black material and on top of the tung and groove? I can't really see if there is. Second, is an insulation layer needed? This house is in NY state. I am wondering what I have and if it is sufficient for a home. Are the heating and AC cost going to be crazy since there is no insulation? If I wanted to add insulation on the top what would you recommend?
















tim 20 months ago
i have aflat roof with 4" of rigid foam under membrane and tar and rock. I was wondering if i could insulate from the inside between joists. it has a drop ceiling .