Insulating Duct Work With Spray Foam Insulation
76Many people spend a great deal of money buying new furnaces and new air conditioners that have 98% efficiency ratings. That is great! I am a big advocate for energy efficiency. However, how efficient is a furnace of central air unit if the duct work is full of leaks?
Metal is not easy to work with. It can only be bent certain ways and pieces of metal are put together to form a piece of duct work. The duct work usually does not fit perfectly together and thus there are leaks. These leaks are responsible for about 20% of the loss of efficiency of a heating or cooling system. So how do you fix it? Simple. Seal the duct work.
Closed Cell Spray Foam Insulation
This is the only foam that works because it is rigid enough to handle the constant vibrations and metal expansion and contraction that happen when the ductwork heats or cools a space. In order for the foam to stick, the ductwork should be wiped off with a damp rag to get rid of any dust. Also it will get rid on the oil used to manufacture the duct if it is galvanized metal. The seams should be sprayed first to ensure that all of the air leaks have been sealed. Then the system can be tested simply by running the fan. After the seams are sealed, a flash coat of approximately 3/4 of an inch should be applied to prevent heat loss in the winter time.
This is a job that you can probably do yourself with a portable spray foam kit. These cost about $400 for 200 board feet. After you seal the duct work, you would have more than enough left over to do the box sills which would add to your efficiency.
Please note that only the supply duct work should be sealed. Sealing the return duct work will not make any difference in efficiency.
The other method of sealing duct work is using a product called Duct mastic. It is a plaster like material that you apply with your hand. Simply put on a rubber glove, dip your hand in the container, and wipe over the leaky areas. Allow 2-4 hours to dry and test for leaks. This is for sealing only and costs roughly $60.
If you are not sure about energy efficiency upgrades or would like to know more methods, hire an energy consultant. They will walk through your building with you to discuss the energy upgrades that will give you most savings. Rebates may be available depending on the state you live in.
CommentsLoading...
"Sealing the return duct work will not make any difference in efficiency"
I don't think this is true. If the air is pulled from the attic or crawlspace instead of your house enveloper not only you pull all that dust into your house you're pulling cold air from outside as well.
Your indoor Air Quality should be measured if you are pulling your air out of your attic or crawlspace.
Talk to your HVAC contractor because it could be a health issue. If you need help on DIY kits to foam your ducts, check out http://www.sprayfoamsys.com
"Sealing the return duct work will not make any difference in efficiency"
You should re-evaluate this comment. Just like supply ducts, return ducts are made of the same metal that is hard to work with. Even worse, returns are often routed through building cavities, such as a drywall box underneath your air handler(platform return). These platform returns worse case have OPEN wall cavities that run all the way to the attic, best case have spaces between bottom and top plates that lead to attic. A 15% return leak pulling 115 degree air from an attic will cut the SEER of your AC in half. Don't have numbers from the study for cold climate, but it will kill the efficiency of your furnace also(having to heat zero degree air instead of slightly under room temp.) Return air leaks will also cause pressurization of your home because the system is supplying more air to the home than what it is pulling out.(since it gets some of its air from the leak) This pushes conditioned air outside the envelope through all penetrations.
I was referring to existing homes on a retrofit basis - specifically platform returns usually located beneath the air handler in an interior closet or the garage. Common setup from the 60's to present. The "open to the attic" part is unintentional. It is duct leakage. It can and should be sealed. It is legitimate design but will pull air from the walls if not sealed properly with mastic or lining wall cavities with duct board or drywall and sealing all seams and edges.
Return duct work leakage WILL effect the efficiency of the system in two ways. First, it pulls cavity air into the return stream - cavity air that can be at 0 degrees or 130degrees. Research shows a 15% return leak from the attic can decrease the effective capacity and efficiency of an air conditioner by 50% (see FSEC-PF-217-96). It is worse in cold weather if you have a heat pump, the cold air stream may kick in your electric heat strips.
The second effect of sealing your supply leakage and leaving your return leakage is that you can create a positive pressure in your home. If you deliver 100% of the supply air flow from the blower and return 90% back to the unit and 10% from your leakage source (attic), then you create a positive pressure in the home. This forces your expensive conditioned air out every penetration it can find.
I seal a lot of duct systems guided by a blower door. If there is a platform return, it often is the largest source of duct leakage and typically accounts for 25-50% of the total system leakage.
Hey Craig,
I apologize. You are talking about air handling systems in Southern climates or climates where cooling rahter than heating is the main concern. This type of system is not typical in Northern states where the majority of the ductwork is most often present in conditioned space (typically a basement or crawlspace). For these types of systems, there is significantly less overall leakage and none of the ductwork is exposed to temperatures that are much warmer or cooler than the conditioned space. In many homes pre 1960, the return ducts are not ductwork at all but simply empty interior wall cavities that have been blocked with wood and sheet metal fastened to the floor joists where it is dumped via what it more commonly seen as return ductwork near the furnace (commonly called a floor return). The second part of that is that most homes in Northern climates that are pre 1950's are multi-story homes so there is a large amount of ductwork that simply cannot be sealed unless you are going to do a lot of wall demolition so I would argue that sealing the return ductwork in these types of systems would see the 15% efficiency drop that you see with your attic air handling systems. That and the fact that most of your air leakage is around the platform return. The other part of that is that warm air and cold air travel much differently through ductwork. So much so that ducts are sized much larger in northern climates as opposed to southern climates to allow for proper air flow between winter and summer months because there is a large emphasis put on heating rather than cooling but the air handler is utilizing the same set of ductwork, central A/C systems often under perform especially in retrofit applications. One thing I will say that stands for any climate is that a return should not be located in a garage even if it is located in a closet because of the possibility of carbon monoxide fumes being pulled into the system and distributed throughout the house.
I agree that if the ducts are in conditioned space, there is not as much importance of sealing due to lower temperature differences. Isn't it amazing that 1000's and 1000's of homes were built with air handlers in the garage during the construction boom in Arizona? I will admit that usually the returns are not open in anyway to the garage - they are encased in drywall so the likelihood of pulling CO is remote. The big problem is being open to the interior walls which in turn are connected with the attic.
















KeithTax Level 4 Commenter 2 years ago
I skipped the ductwork when insulating with closed cell spray foam. Instead, I taped the conections and wrapped the ducts in fiberglass duct insulation. I am interested how much added efficiency I would gain by changing to spray on closed cell foam on my ducts.